Agilent 6890N Gas Chromatograph G1530N w/ FID Detector EPC type 2 S/SL
Worldwide delivery
3-day handling
Free US shipping
with no fees
15% off
on any second item
Couldn't load pickup availability
We welcome reasonable offers and can ship worldwide. Please get in touch with us with any questions regarding configuration, compatibility, shipping, or international freight. We offer 30-day returns!
Please read carefully:
• Used, tested. The Agilent 6890N powers on successfully and recognizes the installed Front FID detector and Front Split/Splitless (S/SL) inlet. The oven was tested and successfully reached the selected 110°C setpoint. The FID and S/SL inlet heaters were also activated and responded to their selected temperature settings.
• The system was tested without carrier/detector gases, and no analytical sample or chromatographic run was performed.
• Preventive Maintenance and Qualification were performed on August 5, 2025, with the next service due August 2026, according to the attached service label. An additional equipment label shows an OQPC date of April 27, 2026.
Please review the pictures and testing photos for additional details. Only what is shown in the pictures is included
CONFIGURATION:
• Agilent 6890N Network GC
• Model: G1530N
• FID (Flame Ionization Detector)
• Split/Splitless (S/SL) Inlet
• Electronic Pneumatics Control (EPC) Type 2
• LAN / Network Port
• 120V Configuration
SPECIFICATIONS:
* Oven Temperature Range: Ambient +4°C to 450°C
* Maximum Run Time: 999.99 minutes
* Oven Programming: Up to 6 temperature ramps
* Carrier Gas Selection: Hydrogen, Helium, Nitrogen, and Argon/Methane
* The 6890N platform supports multiple detector configurations, including FID, ECD, NPD, and TCD, depending on the installed hardware and application.
* Compatible 6890N configurations may be used with Agilent autosampler and MSD platforms, depending on the installed hardware, software, communication interface, and configuration.
Only what is shown in the pictures is included.
Brand: Agilent
MPN: G1530N
Model: 6890N Network
Type: Gas Chromatograph System
Used with: Agilent 7673 Autosampler, Agilent 5973 5975 MSD Detectors
SN: US10249149
Country of Origin: US
HS Code: 9027.20.2000
Used
Tested. The system powers on successfully and completes its startup/self-diagnostic sequence. The system recognizes the installed FID detector and S/SL inlet configuration. Preventive maintenance documentation/tag from FullSpectrum shows PM due August 2026. The unit is in very good overall condition and comes in an Agilent shipping box. Please review all pictures carefully for the exact condition and configuration.
140lbs
G1530N
United States Shipping
This product qualifies for free shipping to the continental U.S.
International Shipping
We ship internationally. Buyers are responsible for any import duties, taxes, or customs requirements. Contact us to request an invoice for customs clearance. We recommend checking with your local customs authority before purchasing.
Overnight Shipping
We are happy to accommodate expedited shipping using your UPS or FedEx account. Please contact us to provide your account information.
This product qualifies for a free return.
We have a 30-day return policy from the date of receipt.
To learn more please visit our Return Policy.